ACCESSORIES ENCLOSURE
-
AIR CIRCUIT BREAKER (ACB)
-
AUTOMATIC TRANSFER SWITCH
-
BACS, BATTERY & BATTERY CHARGER
-
BUSBAR SYSTEM
-
BUSDUCT & CABLE TRAY
-
CABLE SYSTEM
-
CHANGE OVER SWITCH
-
CURRENT TRANSFORMER & VOLTAGE TRANSFORMER
-
DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
EARTH LEAKAGE CIRCUIT BREAKER (ELCB)
-
EARTHING SWITCHES
-
FUSE
-
HAZARDOUS AREA
-
INSULATION BUSBAR SYSTEM
-
INSULATOR SYSTEM
-
LAMP, PUSH BUTTON & SWITCHES
-
LV DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
MAGNETIC CONTACTOR & OVERLOAD STARTER
-
MCC DRAWER COMPONENTS
-
METERS
-
MINIATURE CIRCUIT BREAKER (MCB)
-
MOLDED CASE CIRCUIT BREAKER (MCCB)
-
OUTDOOR ELECTRICAL COMPONENTS
-
POWER FACTOR CORRECTION
-
PROTECTION RELAYS
-
RESISTOR SYSTEM
-
RETROFIT, RETROFILL & PREVENTIVE MAINTENANCE
-
SCADA & AUTOMATION
-
SOFTSTARTER
-
SURGE ARRESTER
-
TERMINATION SYSTEM
-
TIMER & RELAYS
-
TOOLS & MEASUREMENTS
-
TRANSFORMER
-
UNINTERRUPTIBLE POWER SUPPLY (UPS)
-
VACUUM CIRCUIT BRAKER
-
VACUUM CONTACTOR SWITCH
-
VARIABLE SPEED DRIVE (INVERTER)
EATON - XAP Series Busduct
XAP Series Busduct As a combination of technical performance and attractive design, XAP series busduct systems have a good performance in flexibility and reliability. Compact design enables low impedance, low voltage drop and line losses. The current range cover 250A to 6300A, range for factory, date centers, commercial areas. XAP series busduct provides complete range of units: elbow, expansion joint, settlement, soft connection and so on. Applicable for vertical or horizontal installation.
Features
• XAP series busduct systems are thoroughly tested and fully comply with GB7251.1/.6 and IEC61439-1/-6. CCC, CB and KEMA certifications are available.
• The busduct is resistant to flame propagation according to IEC61439-6 10.101~102. And the anti-seismic and vibration performance of AG3 is tested positively according to IEC60068.
• Protection against mechanical impact meets IK10 according to IEC 62262.
• The range extends from 250A to 6300A with a wide selection of accessories. Both straight length and tap-off units are available.
• Up to 10 tap-off outlets for a standard 3m length, which allows easy changes in layout with reserved joints.
• Feed units apply to IP 65 and tap-off units apply to IP54.
• Hard copper conductor with 99.95% purity for electrical engineering enables low impedance, lower voltage drop and line losses.
• High grounding performance is secured by adopting earth busduct which is above 50% of phase line busduct capacity.
• Mylar EL polyester film is used for insulation which can meet 10kV per layer. heat-resisting can achieve Class B 130ºC. Halogen free and toxic gas free while burning. Test report from 3rd part lab is available.
• Lightweight magaluma (aluminium-magnesium alloy) housing ensures the busdut has lower magnetic loss, better heat dissipation and be environmental friendly.
• Side surface of U-shape is processed to dentate structure with more radiating area and higher stiffness. This ensures higher thermal resistance, mechanical strength and dynamic-thermal stability.
• Fit-for-purpose for Eaton’s DX series switchboards and panel boards.