ACCESSORIES ENCLOSURE
-
AIR CIRCUIT BREAKER (ACB)
-
AUTOMATIC TRANSFER SWITCH
-
BACS, BATTERY & BATTERY CHARGER
-
BUSBAR SYSTEM
-
BUSDUCT & CABLE TRAY
-
CABLE SYSTEM
-
CHANGE OVER SWITCH
-
CURRENT TRANSFORMER & VOLTAGE TRANSFORMER
-
DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
EARTH LEAKAGE CIRCUIT BREAKER (ELCB)
-
EARTHING SWITCHES
-
FUSE
-
HAZARDOUS AREA
-
INSULATION BUSBAR SYSTEM
-
INSULATOR SYSTEM
-
LAMP, PUSH BUTTON & SWITCHES
-
LV DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
MAGNETIC CONTACTOR & OVERLOAD STARTER
-
MCC DRAWER COMPONENTS
-
METERS
-
MINIATURE CIRCUIT BREAKER (MCB)
-
MOLDED CASE CIRCUIT BREAKER (MCCB)
-
OUTDOOR ELECTRICAL COMPONENTS
-
POWER FACTOR CORRECTION
-
PROTECTION RELAYS
-
RESISTOR SYSTEM
-
RETROFIT, RETROFILL & PREVENTIVE MAINTENANCE
-
SCADA & AUTOMATION
-
SOFTSTARTER
-
SURGE ARRESTER
-
TERMINATION SYSTEM
-
TIMER & RELAYS
-
TOOLS & MEASUREMENTS
-
TRANSFORMER
-
UNINTERRUPTIBLE POWER SUPPLY (UPS)
-
VACUUM CIRCUIT BRAKER
-
VACUUM CONTACTOR SWITCH
-
VARIABLE SPEED DRIVE (INVERTER)
Distribution Relay (EDR 3000 or 5000)
Eaton Distribution Relay (EDR 3000 / 5000) The EDR is a multi-functional, microprocessor-based relay for feeder circuits of all voltage levels. It may be used as a primary protection on feeders, mains and tie circuit breaker applications; or as backup protection for transformers, high voltage lines and differential protection. The relay is most commonly used on medium voltage switchgear applications.
Eaton Distribution Relay (EDR 3000 or 5000)
Features
• Complete metering, protection, and control in a single compact case to reduce panel space, wiring and costs.
• Intuitive programming substantially reduces operator training time and provides unmatched operability and flexibility.
• Integral test function reduces maintenance time and expense.
• Zone selective interlocking improves coordination and tripping time, and saves money compared to a traditional bus differential scheme.
• Multiple operator selectable protective functions reduce arc flash energy and zone selective interlocking for bus protection, eliminating the need of additional CTs or relays.
• Reduce trouble shooting time and maintenance costs-Trip and event recording in non-volatile memory provides detailed information for analysis and system restoration. 6000 cycles of waveform capture aids in post fault analysis (viewable using Powerport-E software).
• Minimum replacement time-Removable terminal blocks ideal in industrial environments.
• Breaker open/close from relay faceplate or remotely via communications.
• Fast and easy troubleshooting, improved maintenance procedures and increased device security. Provides detailed traceability for system configuration changes.
• Relays self-diagnostics and reporting improves uptime and troubleshooting.
• Breaker trip circuit monitoring improves the reliability of the breaker operation.