-
ACCESSORIES ENCLOSURE
-
AIR CIRCUIT BREAKER (ACB)
-
AUTOMATIC TRANSFER SWITCH
-
BACS, BATTERY & BATTERY CHARGER
-
BUSBAR SYSTEM
-
BUSDUCT & CABLE TRAY
-
CABLE SYSTEM
-
CHANGE OVER SWITCH
-
CURRENT TRANSFORMER & VOLTAGE TRANSFORMER
-
DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
EARTH LEAKAGE CIRCUIT BREAKER (ELCB)
-
EARTHING SWITCHES
-
FUSE
-
HAZARDOUS AREA
-
INSULATION BUSBAR SYSTEM
-
INSULATOR SYSTEM
-
LAMP, PUSH BUTTON & SWITCHES
-
LV DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
MAGNETIC CONTACTOR & OVERLOAD STARTER
-
MCC DRAWER COMPONENTS
-
METERS
-
MINIATURE CIRCUIT BREAKER (MCB)
-
MOLDED CASE CIRCUIT BREAKER (MCCB)
-
OUTDOOR ELECTRICAL COMPONENTS
-
POWER FACTOR CORRECTION
-
PROTECTION RELAYS
-
RESISTOR SYSTEM
-
RETROFIT, RETROFILL & PREVENTIVE MAINTENANCE
-
SCADA & AUTOMATION
-
SOFTSTARTER
-
SURGE ARRESTER
-
TERMINATION SYSTEM
-
TIMER & RELAYS
-
TOOLS & MEASUREMENTS
-
TRANSFORMER
-
UNINTERRUPTIBLE POWER SUPPLY (UPS)
-
VACUUM CIRCUIT BRAKER
-
VACUUM CONTACTOR SWITCH
-
VARIABLE SPEED DRIVE (INVERTER)
Motor Relay (EMR 3000 or 4000 or 5000)
Eaton Motor Relay (EMR 3000 / 4000 / 5000) Eaton’s EMR motor protection relay is a multifunctional microprocessor-based protective relay for the protection of any size motor at all voltage levels. It is most commonly applied on medium voltage or larger motors. The EMR relay is a current and voltage device with built in differential protection that provides complete and reliable motor protection, monitoring, diagnostics, metering, and starting control functions.
Features
• Integral test function reduces maintenance time and expense.
• Zone selective interlocking improves coordination and tripping time, and saves money compared to a traditional bus differential scheme.
• Programmable logic control functions to accommodate different control schemes, simplify the wiring of the starter.
• Automatically detects direction of the motor and eliminates the need of switching current inputs into the relay.
• Reduce trouble shooting time and maintenance costs- Trip and event recording in non-volatile memory provides detailed information for analysis and system restoration. 6000 cycles of waveform capture aids in post fault analysis (viewable using Powerport-E software).
• Minimum replacement time- Removable terminal blocks ideal in industrial environments.
• Front RS-232 port and Powerport-E software provides local computer access and user-friendly windows based interface for relay settings, configuration, and data retrieval.
• Breaker open/close from relay faceplate or remotely via communications.
• Fast an easy troubleshooting, improved maintenance procedures and increased device security. Provides detailed traceability for system configuration changes.
• Relays self-diagnostics and reporting improves uptime and troubleshooting.
• Breaker trip circuit monitoring improves the reliability of the breaker operation.
• Reduced relay to relay wiring and associated installation cost through high-speed inter-relay communications.
• Embedded IEC61850 protocol with GOOSE messaging capabilities