ACCESSORIES ENCLOSURE
-
AIR CIRCUIT BREAKER (ACB)
-
AUTOMATIC TRANSFER SWITCH
-
BACS, BATTERY & BATTERY CHARGER
-
BUSBAR SYSTEM
-
BUSDUCT & CABLE TRAY
-
CABLE SYSTEM
-
CHANGE OVER SWITCH
-
CURRENT TRANSFORMER & VOLTAGE TRANSFORMER
-
DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
EARTH LEAKAGE CIRCUIT BREAKER (ELCB)
-
EARTHING SWITCHES
-
FUSE
-
HAZARDOUS AREA
-
INSULATION BUSBAR SYSTEM
-
INSULATOR SYSTEM
-
LAMP, PUSH BUTTON & SWITCHES
-
LV DISCONNECTING SWITCH & LOAD BREAK SWITCH
-
MAGNETIC CONTACTOR & OVERLOAD STARTER
-
MCC DRAWER COMPONENTS
-
METERS
-
MINIATURE CIRCUIT BREAKER (MCB)
-
MOLDED CASE CIRCUIT BREAKER (MCCB)
-
OUTDOOR ELECTRICAL COMPONENTS
-
POWER FACTOR CORRECTION
-
PROTECTION RELAYS
-
RESISTOR SYSTEM
-
RETROFIT, RETROFILL & PREVENTIVE MAINTENANCE
-
SCADA & AUTOMATION
-
SOFTSTARTER
-
SURGE ARRESTER
-
TERMINATION SYSTEM
-
TIMER & RELAYS
-
TOOLS & MEASUREMENTS
-
TRANSFORMER
-
UNINTERRUPTIBLE POWER SUPPLY (UPS)
-
VACUUM CIRCUIT BRAKER
-
VACUUM CONTACTOR SWITCH
-
VARIABLE SPEED DRIVE (INVERTER)
Phase Protection Relays
Phase protection relays continuously monitor a three phase AC power supply, tripping upon fault condition. These relays protect against total loss of a phase (phase failure), incorrect phase sequence (rotation), symmetrical under voltage and asymmetrical under voltage. The A866PSI model also offers phase sequence and fault indication. The internal relay remains energised and the LED illuminates only when the power supply is satisfactory for connection to the three phase equipment. The under volt
Phase Protection Relays
Product Features
. Protects against loss of phase and incorrect phase sequence
. Protects against phase reversal and under voltage
. LED indication
. DIN rail mounting
. Single or double pole output available
. Optional built-in time delay
Phase protection relays continuously monitor a three phase AC power supply, tripping upon fault condition. These relays protect against total loss of a phase (phase failure), incorrect phase sequence (rotation), symmetrical under voltage and asymmetrical under voltage. The A866PSI model also offers phase sequence and fault indication. The internal relay remains energised and the LED illuminates only when the power supply is satisfactory for connection to the three phase equipment. The under voltage trip point on all three phases is fixed at 85% of the nominal voltage, although an alternative trip point may be possible upon request. The relays are self powered, requiring no auxiliary power supply and are available with either a single or double pole changeover relay output and optional built-in time delay.
Technical Data
Â